{"product_id":"magnetic-particle-testing","title":"Magnetic Particle Testing","description":"\u003cp\u003e\u003cstrong\u003eWhat is Magnetic Testing (MT)?\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eMagnetic Testing is a non-destructive method used to detect surface and near-surface defects in ferromagnetic materials. The method works by generating magnetic fields using magnetic particle indicators or probes, which reveal discontinuities when magnetic particles accumulate in areas of flux leakage.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eMagnetic testing is applicable only to ferromagnetic materials such as steel and nickel. It is widely used in industries such as civil engineering, railway transport, aviation, and oil \u0026amp; gas.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplications of Magnetic Testing:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-list=\"bullet\"\u003e\n\u003cstrong\u003eDiscontinuity detection\u003c\/strong\u003e: Identifying voids, cracks, and other defects within the material.\u003c\/li\u003e\n\u003cli data-list=\"bullet\"\u003e\n\u003cstrong\u003eCoating thickness measurement\u003c\/strong\u003e: Measuring the thickness of nonmagnetic coatings applied to ferromagnetic materials.\u003c\/li\u003e\n\u003cli data-list=\"bullet\"\u003e\n\u003cstrong\u003eMagnetic structure analysis\u003c\/strong\u003e: Analyzing the material structure based on its magnetic properties.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhy Choose Our Magnetic Testing Course?\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eOur \u003c\/span\u003e\u003cstrong\u003eMagnetic Testing course\u003c\/strong\u003e\u003cspan\u003e will teach you the essential skills for performing magnetic inspections and understanding the magnetic properties of materials.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eIn this course, you will learn:\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-list=\"bullet\"\u003e\n\u003cstrong\u003eMagnetic field generation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand how it reveals defects.\u003c\/li\u003e\n\u003cli data-list=\"bullet\"\u003e\n\u003cstrong\u003eHow to detect and measure imperfections\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein ferromagnetic materials.\u003c\/li\u003e\n\u003cli data-list=\"bullet\"\u003e\n\u003cstrong\u003eTechniques for measuring coating thickness\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand analyzing magnetic structures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdvantages of Magnetic Testing:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-list=\"bullet\"\u003e\n\u003cstrong\u003eFast and easy interpretation\u003c\/strong\u003e: Magnetic particle testing allows for quick identification of defects.\u003c\/li\u003e\n\u003cli data-list=\"bullet\"\u003e\n\u003cstrong\u003eSensitive to surface imperfections\u003c\/strong\u003e: Highly effective for detecting surface and subsurface defects.\u003c\/li\u003e\n\u003cli data-list=\"bullet\"\u003e\n\u003cstrong\u003eNo need to clean internal surfaces\u003c\/strong\u003e: Unlike other methods, there is no need to clean internal surfaces before inspection.\u003c\/li\u003e\n\u003cli data-list=\"bullet\"\u003e\n\u003cstrong\u003eEase of repetition\u003c\/strong\u003e: Inspections can be easily repeated, ensuring reliability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDisadvantages of Magnetic Testing:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-list=\"bullet\"\u003e\n\u003cstrong\u003eLimited to ferromagnetic materials\u003c\/strong\u003e: The method can only be applied to materials like steel and nickel.\u003c\/li\u003e\n\u003cli data-list=\"bullet\"\u003e\n\u003cstrong\u003eSurface and subsurface imperfections only\u003c\/strong\u003e: Magnetic testing cannot detect internal defects deep within the material.\u003c\/li\u003e\n\u003cli data-list=\"bullet\"\u003e\n\u003cstrong\u003eWaste and ecological impact\u003c\/strong\u003e: Magnetic particle testing generates waste, which can have an environmental impact.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin: 0cm;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 16.0pt; color: #003300; mso-font-kerning: 12.0pt; mso-ansi-language: EN-US;\" lang=\"EN-US\"\u003eMAGNETIC PARTICLE TESTING \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0cm;\"\u003e\u003cspan style=\"font-size: 16.0pt; color: #003300; mso-font-kerning: 12.0pt; mso-ansi-language: EN-US;\" lang=\"EN-US\"\u003e2\u003csup\u003end\u003c\/sup\u003e Qualification Level\u003c\/span\u003e\u003cspan style=\"mso-ansi-language: EN-US;\" lang=\"EN-US\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"mso-ansi-language: EN-US;\" lang=\"EN-US\"\u003eTraining Program Outline (20 hours total)\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 402.4pt; border-collapse: collapse; mso-yfti-tbllook: 1536; mso-padding-alt: 0cm 0cm 0cm 0cm;\" width=\"537\" cellpadding=\"0\" cellspacing=\"0\" border=\"0\" class=\"MsoNormalTable\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes; height: 31.9pt;\"\u003e\n\u003ctd style=\"width: 344.2pt; border: solid black 1.0pt; padding: .75pt 5.75pt 0cm 5.75pt; height: 31.9pt;\" valign=\"top\" width=\"459\"\u003e\n\u003cp\u003e\u003cb\u003eTopic of Training\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 58.2pt; border: solid black 1.0pt; border-left: none; mso-border-left-alt: solid black 1.0pt; padding: .75pt 5.75pt 0cm 5.75pt; height: 31.9pt;\" valign=\"top\" width=\"78\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cb\u003eDuration\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 1; height: 21.8pt;\"\u003e\n\u003ctd style=\"width: 344.2pt; border: solid black 1.0pt; border-top: none; mso-border-top-alt: solid black 1.0pt; padding: .75pt 5.75pt 0cm 5.75pt; height: 21.8pt;\" valign=\"top\" width=\"459\"\u003e\n\u003cp\u003eMaterials and production technology\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 58.2pt; border-top: none; border-left: none; border-bottom: solid black 1.0pt; border-right: solid black 1.0pt; mso-border-top-alt: solid black 1.0pt; mso-border-left-alt: solid black 1.0pt; padding: .75pt 5.75pt 0cm 5.75pt; height: 21.8pt;\" valign=\"middle\" width=\"78\"\u003e\n\u003cp style=\"text-align: center;\"\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2; height: 31.9pt;\"\u003e\n\u003ctd style=\"width: 344.2pt; border: solid black 1.0pt; border-top: none; mso-border-top-alt: solid black 1.0pt; padding: .75pt 5.75pt 0cm 5.75pt; height: 31.9pt;\" valign=\"top\" width=\"459\"\u003e\n\u003cp\u003e\u003cspan style=\"mso-ansi-language: EN-US;\" lang=\"EN-US\"\u003eGeneral physics of magnetic testing (magnetism, magnetic field parameters, electrical circuits)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 58.2pt; border-top: none; border-left: none; border-bottom: solid black 1.0pt; border-right: solid black 1.0pt; mso-border-top-alt: solid black 1.0pt; mso-border-left-alt: solid black 1.0pt; padding: .75pt 5.75pt 0cm 5.75pt; height: 31.9pt;\" valign=\"middle\" width=\"78\"\u003e\n\u003cp style=\"text-align: center;\"\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3; height: 15.95pt;\"\u003e\n\u003ctd style=\"width: 344.2pt; border: solid black 1.0pt; border-top: none; mso-border-top-alt: solid black 1.0pt; padding: .75pt 5.75pt 0cm 5.75pt; height: 15.95pt;\" valign=\"top\" width=\"459\"\u003e\n\u003cp\u003e\u003cspan style=\"mso-ansi-language: EN-US;\" lang=\"EN-US\"\u003eMagnetic particle testing equipment construction and principles of operation (magnetic benches, yokes, coils, indicators, and measurement tools)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 58.2pt; border-top: none; border-left: none; border-bottom: solid black 1.0pt; border-right: solid black 1.0pt; mso-border-top-alt: solid black 1.0pt; mso-border-left-alt: solid black 1.0pt; padding: .75pt 5.75pt 0cm 5.75pt; height: 15.95pt;\" valign=\"middle\" width=\"78\"\u003e\n\u003cp style=\"text-align: center;\"\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4; height: 15.95pt;\"\u003e\n\u003ctd style=\"width: 344.2pt; border: solid black 1.0pt; border-top: none; mso-border-top-alt: solid black 1.0pt; padding: .75pt 5.75pt 0cm 5.75pt; height: 15.95pt;\" valign=\"top\" width=\"459\"\u003e\n\u003cp\u003e\u003cspan style=\"mso-ansi-language: EN-US;\" lang=\"EN-US\"\u003eMPT inspection conditions and sensitivity checks (calibration blocks, field indicators, lux meters)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 58.2pt; border-top: none; border-left: none; border-bottom: solid black 1.0pt; border-right: solid black 1.0pt; mso-border-top-alt: solid black 1.0pt; mso-border-left-alt: solid black 1.0pt; padding: .75pt 5.75pt 0cm 5.75pt; height: 15.95pt;\" valign=\"middle\" width=\"78\"\u003e\n\u003cp style=\"text-align: center;\"\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5; height: 15.95pt;\"\u003e\n\u003ctd style=\"width: 344.2pt; border: solid black 1.0pt; border-top: none; mso-border-top-alt: solid black 1.0pt; padding: .75pt 5.75pt 0cm 5.75pt; height: 15.95pt;\" valign=\"top\" width=\"459\"\u003e\n\u003cp\u003e\u003cspan style=\"mso-ansi-language: EN-US;\" lang=\"EN-US\"\u003eInspection technology and instruction writing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 58.2pt; border-top: none; border-left: none; border-bottom: solid black 1.0pt; border-right: solid black 1.0pt; mso-border-top-alt: solid black 1.0pt; mso-border-left-alt: solid black 1.0pt; padding: .75pt 5.75pt 0cm 5.75pt; height: 15.95pt;\" valign=\"middle\" width=\"78\"\u003e\n\u003cp style=\"text-align: center;\"\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6; height: 15.95pt;\"\u003e\n\u003ctd style=\"width: 344.2pt; border: solid black 1.0pt; border-top: none; mso-border-top-alt: solid black 1.0pt; padding: .75pt 5.75pt 0cm 5.75pt; height: 15.95pt;\" valign=\"top\" width=\"459\"\u003e\n\u003cp\u003eTraining on simulation software\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 58.2pt; border-top: none; border-left: none; border-bottom: solid black 1.0pt; border-right: solid black 1.0pt; mso-border-top-alt: solid black 1.0pt; mso-border-left-alt: solid black 1.0pt; padding: .75pt 5.75pt 0cm 5.75pt; height: 15.95pt;\" valign=\"middle\" width=\"78\"\u003e\n\u003cp style=\"text-align: center;\"\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7; mso-yfti-lastrow: yes; height: 15.95pt;\"\u003e\n\u003ctd style=\"width: 344.2pt; border: solid black 1.0pt; border-top: none; mso-border-top-alt: solid black 1.0pt; padding: .75pt 5.75pt 0cm 5.75pt; height: 15.95pt;\" valign=\"top\" width=\"459\"\u003e\n\u003cp\u003eTraining in report writing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 58.2pt; border-top: none; border-left: none; border-bottom: solid black 1.0pt; border-right: solid black 1.0pt; mso-border-top-alt: solid black 1.0pt; mso-border-left-alt: solid black 1.0pt; padding: .75pt 5.75pt 0cm 5.75pt; height: 15.95pt;\" valign=\"middle\" width=\"78\"\u003e\n\u003cp style=\"text-align: center;\"\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"QualityNDT","offers":[{"title":"Default Title","offer_id":41525425111173,"sku":"MT","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0597\/8393\/8181\/files\/magnetic-testing1.jpg?v=1771614190","url":"https:\/\/quality-ndt.com\/products\/magnetic-particle-testing","provider":"QualityNDT","version":"1.0","type":"link"}