{"product_id":"radiographic-testing","title":"Radiographic Testing","description":"\u003cp\u003e\u003cstrong\u003eWhat is Radiographic Testing (RT)?\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eRadiographic Testing (RT) is a non-destructive method that uses X-ray or gamma-ray radiation to inspect the internal structure of materials. The process involves exposing a part to radiation and analyzing the resulting radiation beam density after it interacts with the material. This technique is effective in revealing internal defects such as cracks, porosity, slag inclusion, and leakage in materials with dimensions larger than 0.1mm.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eRadiographic testing can be applied to all types of materials, including metals and non-metals, and is especially useful for examining the relative position of parts in inaccessible areas. It is widely used in industries such as civil engineering, aviation, and oil \u0026amp; gas.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplications of Radiographic Testing:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-list=\"bullet\"\u003e\n\u003cstrong\u003eDefect detection\u003c\/strong\u003e: Identifying internal defects like cracks, porosity, and slag inclusion.\u003c\/li\u003e\n\u003cli data-list=\"bullet\"\u003e\n\u003cstrong\u003eMaterial inspection\u003c\/strong\u003e: Used for materials of all types (metals and non-metals).\u003c\/li\u003e\n\u003cli data-list=\"bullet\"\u003e\n\u003cstrong\u003eExamination of complex parts\u003c\/strong\u003e: Suitable for inspecting parts that are difficult to access.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhy Choose Our Radiographic Testing Course?\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eOur \u003c\/span\u003e\u003cstrong\u003eRadiographic Testing course\u003c\/strong\u003e\u003cspan\u003e will provide you with the knowledge and practical skills to perform X-ray and gamma-ray inspections effectively.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eIn this course, you will learn:\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-list=\"bullet\"\u003e\n\u003cstrong\u003eHow radiographic testing works\u003c\/strong\u003e: Understand the principles behind X-ray and gamma-ray radiation.\u003c\/li\u003e\n\u003cli data-list=\"bullet\"\u003e\n\u003cstrong\u003ePractical skills\u003c\/strong\u003e: Learn to detect internal discontinuities and assess material integrity.\u003c\/li\u003e\n\u003cli data-list=\"bullet\"\u003e\n\u003cstrong\u003eSafety protocols\u003c\/strong\u003e: Know the safety regulations and licensing requirements for working with radiation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdvantages of Radiographic Testing:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-list=\"bullet\"\u003e\n\u003cstrong\u003eClear interpretation and documented results\u003c\/strong\u003e: Results are captured on film or digital media, providing a permanent record.\u003c\/li\u003e\n\u003cli data-list=\"bullet\"\u003e\n\u003cstrong\u003eDetects internal discontinuities\u003c\/strong\u003e: RT is highly effective at revealing hidden internal defects.\u003c\/li\u003e\n\u003cli data-list=\"bullet\"\u003e\n\u003cstrong\u003eApplicable to all material types\u003c\/strong\u003e: Can be used for both metals and non-metals.\u003c\/li\u003e\n\u003cli data-list=\"bullet\"\u003e\n\u003cstrong\u003eEasy to repeat\u003c\/strong\u003e: Inspections can be easily repeated for verification or consistency.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDisadvantages of Radiographic Testing:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-list=\"bullet\"\u003e\n\u003cstrong\u003eLimited sensitivity to small surface imperfections\u003c\/strong\u003e: RT is primarily effective for internal defects, not small surface flaws.\u003c\/li\u003e\n\u003cli data-list=\"bullet\"\u003e\n\u003cstrong\u003eExposure direction matters\u003c\/strong\u003e: The angle of radiation exposure can influence defect detection.\u003c\/li\u003e\n\u003cli data-list=\"bullet\"\u003e\n\u003cstrong\u003eRadiation protection required\u003c\/strong\u003e: Proper shielding and protection are necessary when using X-ray or gamma-ray equipment, and appropriate licensing is required.\u003c\/li\u003e\n\u003cli data-list=\"bullet\"\u003e\n\u003cstrong\u003eCostly for thick materials\u003c\/strong\u003e: Inspecting materials with thicknesses greater than 50mm (e.g., steel) requires powerful equipment and expensive protective measures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin: 0cm;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 16.0pt; color: #003300; mso-font-kerning: 12.0pt; mso-ansi-language: EN-US;\" lang=\"EN-US\"\u003eRADIOGRAPHIC TESTING (Radiography)\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"mso-ansi-language: EN-US;\" lang=\"EN-US\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0cm;\"\u003e\u003cspan style=\"font-size: 16.0pt; color: #003300; mso-font-kerning: 12.0pt; mso-ansi-language: EN-US;\" lang=\"EN-US\"\u003e2\u003csup\u003end\u003c\/sup\u003e Qualification Level\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"mso-ansi-language: EN-US;\" lang=\"EN-US\"\u003eTraining Program Outline (80 hours total)\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 402.4pt; border-collapse: collapse; mso-yfti-tbllook: 1536; mso-padding-alt: 0cm 0cm 0cm 0cm;\" width=\"537\" cellpadding=\"0\" cellspacing=\"0\" border=\"0\" class=\"MsoNormalTable\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes; height: 31.9pt;\"\u003e\n\u003ctd style=\"width: 348.2pt; border: solid black 1.0pt; padding: .75pt 5.75pt 0cm 5.75pt; height: 31.9pt;\" valign=\"top\" width=\"464\"\u003e\n\u003cp\u003eTopic of Training\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.2pt; border: solid black 1.0pt; border-left: none; mso-border-left-alt: solid black 1.0pt; padding: .75pt 5.75pt 0cm 5.75pt; height: 31.9pt;\" valign=\"top\" width=\"72\"\u003e\n\u003cp\u003eDuration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 1; height: 21.8pt;\"\u003e\n\u003ctd style=\"width: 348.2pt; border: solid black 1.0pt; border-top: none; mso-border-top-alt: solid black 1.0pt; padding: .75pt 5.75pt 0cm 5.75pt; height: 21.8pt;\" valign=\"top\" width=\"464\"\u003e\n\u003cp\u003eMaterials and production technology\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.2pt; border-top: none; border-left: none; border-bottom: solid black 1.0pt; border-right: solid black 1.0pt; mso-border-top-alt: solid black 1.0pt; mso-border-left-alt: solid black 1.0pt; padding: .75pt 5.75pt 0cm 5.75pt; height: 21.8pt;\" valign=\"middle\" width=\"72\"\u003e\n\u003cp style=\"text-align: center;\"\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2; height: 31.9pt;\"\u003e\n\u003ctd style=\"width: 348.2pt; border: solid black 1.0pt; border-top: none; mso-border-top-alt: solid black 1.0pt; padding: .75pt 5.75pt 0cm 5.75pt; height: 31.9pt;\" valign=\"top\" width=\"464\"\u003e\n\u003cp\u003e\u003cspan style=\"mso-ansi-language: EN-US;\" lang=\"EN-US\"\u003eGeneral physics of radiographic testing (X-ray radiation, isotopes, radioactive decay, radiation interaction with media)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.2pt; border-top: none; border-left: none; border-bottom: solid black 1.0pt; border-right: solid black 1.0pt; mso-border-top-alt: solid black 1.0pt; mso-border-left-alt: solid black 1.0pt; padding: .75pt 5.75pt 0cm 5.75pt; height: 31.9pt;\" valign=\"middle\" width=\"72\"\u003e\n\u003cp style=\"text-align: center;\"\u003e18\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3; height: 15.95pt;\"\u003e\n\u003ctd style=\"width: 348.2pt; border: solid black 1.0pt; border-top: none; mso-border-top-alt: solid black 1.0pt; padding: .75pt 5.75pt 0cm 5.75pt; height: 15.95pt;\" valign=\"top\" width=\"464\"\u003e\n\u003cp\u003e\u003cspan style=\"mso-ansi-language: EN-US;\" lang=\"EN-US\"\u003eRadiographic equipment construction and principles of operation (X-ray generators, gamma flaw detectors, films, dosimeters)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.2pt; border-top: none; border-left: none; border-bottom: solid black 1.0pt; border-right: solid black 1.0pt; mso-border-top-alt: solid black 1.0pt; mso-border-left-alt: solid black 1.0pt; padding: .75pt 5.75pt 0cm 5.75pt; height: 15.95pt;\" valign=\"middle\" width=\"72\"\u003e\n\u003cp style=\"text-align: center;\"\u003e12\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4; height: 15.95pt;\"\u003e\n\u003ctd style=\"width: 348.2pt; border: solid black 1.0pt; border-top: none; mso-border-top-alt: solid black 1.0pt; padding: .75pt 5.75pt 0cm 5.75pt; height: 15.95pt;\" valign=\"top\" width=\"464\"\u003e\n\u003cp\u003e\u003cspan style=\"mso-ansi-language: EN-US;\" lang=\"EN-US\"\u003eRadiographic sensitivity checks (image quality indicators, radiographic markers)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.2pt; border-top: none; border-left: none; border-bottom: solid black 1.0pt; border-right: solid black 1.0pt; mso-border-top-alt: solid black 1.0pt; mso-border-left-alt: solid black 1.0pt; padding: .75pt 5.75pt 0cm 5.75pt; height: 15.95pt;\" valign=\"middle\" width=\"72\"\u003e\n\u003cp style=\"text-align: center;\"\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5; height: 15.95pt;\"\u003e\n\u003ctd style=\"width: 348.2pt; border: solid black 1.0pt; border-top: none; mso-border-top-alt: solid black 1.0pt; padding: .75pt 5.75pt 0cm 5.75pt; height: 15.95pt;\" valign=\"top\" width=\"464\"\u003e\n\u003cp\u003e\u003cspan style=\"mso-ansi-language: EN-US;\" lang=\"EN-US\"\u003eInspection technology and instruction writing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.2pt; border-top: none; border-left: none; border-bottom: solid black 1.0pt; border-right: solid black 1.0pt; mso-border-top-alt: solid black 1.0pt; mso-border-left-alt: solid black 1.0pt; padding: .75pt 5.75pt 0cm 5.75pt; height: 15.95pt;\" valign=\"middle\" width=\"72\"\u003e\n\u003cp style=\"text-align: center;\"\u003e12\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6; height: 15.95pt;\"\u003e\n\u003ctd style=\"width: 348.2pt; border: solid black 1.0pt; border-top: none; mso-border-top-alt: solid black 1.0pt; padding: .75pt 5.75pt 0cm 5.75pt; height: 15.95pt;\" valign=\"top\" width=\"464\"\u003e\n\u003cp\u003eTraining on simulation software\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.2pt; border-top: none; border-left: none; border-bottom: solid black 1.0pt; border-right: solid black 1.0pt; mso-border-top-alt: solid black 1.0pt; mso-border-left-alt: solid black 1.0pt; padding: .75pt 5.75pt 0cm 5.75pt; height: 15.95pt;\" valign=\"middle\" width=\"72\"\u003e\n\u003cp style=\"text-align: center;\"\u003e24\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7; mso-yfti-lastrow: yes; height: 15.95pt;\"\u003e\n\u003ctd style=\"width: 348.2pt; border: solid black 1.0pt; border-top: none; mso-border-top-alt: solid black 1.0pt; padding: .75pt 5.75pt 0cm 5.75pt; height: 15.95pt;\" valign=\"top\" width=\"464\"\u003e\n\u003cp\u003eTraining in report writing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.2pt; border-top: none; border-left: none; border-bottom: solid black 1.0pt; border-right: solid black 1.0pt; mso-border-top-alt: solid black 1.0pt; mso-border-left-alt: solid black 1.0pt; padding: .75pt 5.75pt 0cm 5.75pt; height: 15.95pt;\" valign=\"middle\" width=\"72\"\u003e\n\u003cp style=\"text-align: center;\"\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"QualityNDT","offers":[{"title":"Default Title","offer_id":41524970455173,"sku":"RT","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0597\/8393\/8181\/files\/radiographic-testing.jpg?v=1771613861","url":"https:\/\/quality-ndt.com\/products\/radiographic-testing","provider":"QualityNDT","version":"1.0","type":"link"}